CyberPower PDU24004 Modular PDU

  • Part: 1756512
  • Model: PDU24004
$968.00

Availability

In Stock

  • General Information
    • Manufacturer
    • CyberPower Systems, Inc
    • Manufacturer Website Address
    • https://www.cyberpower.com/au
    • Brand Name
    • CyberPower
    • Product Series
    • Switched ATS PDU
    • Product Type
    • PDU

Ensure continued operation of critical devices with the CyberPower PDU24004 Metered ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.

The PDU24004 supports inputs between 200-240V and includes (12) IEC C13 outlets. Dual IEC C14 power cords are plugged into separate power sources (A and B), and information about each power source is provided via LED indicator lights on the front of the unit. Other features include an LCD with selectable background color, ugradeable firmware, and network-grade plugs and outlets. The CyberPower PDU24004 is protected by a three-year limited warranty.

  • Technical Information
    • PDU Type
    • Metered
    • Design
    • Modular
    • Phase
    • Single Phase
    • Plug/Connector Type
    • IEC 60320 C14
    • Plug/Connector Detail
    • 2 x IEC 60320 C14
    • Receptacle Type
    • IEC 60320 C13
    • Receptacle Detail
    • 12 x IEC 60320 C13
  • Power Description
    • Input Voltage Range
    • 200 V AC - 240 V AC
    • Output Voltage
    • 230 V AC
    • Output Voltage Range
    • 200 V AC - 240 V AC
    • Input Current
    • 15 A
  • Management
    • Management
      • IPv4
      • TCP/IP
      • UDP
      • SNMPv1
      • HTTP
      • NTP
      • DNS
      • Telnet
      • DHCP
      • SMTP
      • FTP
      • IPv6
      • SNMPv3
      • HTTPs
      • SSH
      • SSL
      • TLS
      • LDAP(S)
      • RADIUS
      • Syslog
      • CLI
      • Windows AD
  • Interfaces/Ports
    • Network (RJ-45)
    • Yes
  • Physical Characteristics
    • Product Color
    • Black
    • Mounting Orientation
    • Horizontal
    • Mount Type
    • Rack-mountable
    • Rack Height
    • 1U
    • Height
    • 44.5 mm
    • Width
    • 433.1 mm
    • Depth
    • 214.6 mm
    • Weight (Approximate)
    • 3.36 kg
  • Miscellaneous
    • Additional Information
      • Cord Length: 10 ft (3.0 m)
      • Derated Input Current: 12 A
      • Input Frequency Range: 50 Hz - 60 Hz
      • Input Overload Protection: 15A x 2
      • Input Plug Type: 2 x IEC-320 C14
      • Maximum Input Current: 15A
      • Nominal Input Voltage: 200 - 240 VAC
      • Phase: Single Phase
      • Plug Style: Straight (Socket)
      • Nominal Output Voltage: 200 - 240 VAC
      • Outlet Banks: 1
      • Outlets - Total: 12
      • Outlet Type COMPUTED: 12 - IEC-320 C13
      • Overload Protection: None
      • Power Source Transfer Time: 2-7 ms
      • Source Failure Detection Time: 2-3 ms
      • Total Transfer Time: <10 ms
      • Hardware Connection Port: Serial (RJ45)
      • LCD: Multifunction LCD
      • LED Indicators: Source Status
      • Upgradeable firmware: Yes
      • Color: Black
      • Cord Retention Tray/Cord Organizers: Yes
      • External Site Ground Pin: Yes
      • Material of Construction: Metal
      • Operating Elevation: 0 - 13123 ft (0 - 4000 m)
      • Operating Relative Humidity: 0 - 95 % (non-condensing)
      • Operating Temperature: 32 - 113 °F (0 - 45 °C)
      • Storage Elevation: 0 - 49213 ft (0 - 14999 m)
      • Storage Temperature: 5 - 131 °F (-15 - 55 °C)
      • Safety: UL62368: FCC Class A: cTUVus/CE/UKCA